Basic-RO series is basic choice for general washing pure water. Its output ranges from 15 to 45 liters/hour. Its ion rejection rate: 97%-99% (new RO membrane), organic rejection rate>99% (when MW>200 dalton), particles and bacteria rejection rate>99%.
Send Inquiry
Description

'Harmony, practice, innovation, and service' are the basic principles of our company. We are willing to work together with people from all walks of life for the bright future of the lab water deionizer, ro di deionizer, Lab Ultrapure Water Systems industry and make contributions to the rapid development of the industry. We advocate simplicity and simplicity of personality, to do simple work well is not simple. With the strong scientific and technological research and development strength, perfect strict quality assurance system and sophisticated production and testing equipment, our company keeps forging ahead and developing. We grow together with our customers, suppliers, employees and shareholders and pursue win-win situation. We have been focused and persistent, so that our products and services continue to improve.

Basic-RO series is basic choice for general washing pure water. Its output ranges from 15 to 45 liters/hour. Its ion rejection rate: 97%-99% (new RO membrane), organic rejection rate>99% (when MW>200 dalton), particles and bacteria rejection rate>99%.


image001

Models:

Basic-RO15 / 30 / 45

Basic-RO15 / 30 / 45-IT


Features and Advantages

Automatic microcomputer controlling system, backlight LCD real-time animation mode display.

Running status is showed in the LCD display, such as flushing, producing water, water full, water shortage, and check service.

2 way online water quality sensors, detect the quality of inlet water, RO water respectively.

Power on self-test, power reset, alarm when work more than 6 hours continuously, water shortage, low and high pressure.

Cartridges replacing alarm function, show cartridges´ used and residual life.

4 procedure of the reverse osmosis membrane´s self-flushing: power on, water shortage reset, water full stop and work more than 2 hours continuously, extend the life of RO membrane.

2 kind of installation type, Desk and wall-mounted (except for 45 series and built-in tank model).

High-strength metal shell with powder painting technics, achieve elegant appearance and meeting GLP standard

Pretreatment cartridges, RO module, all designed to modularization independently, easy for maintenance and replacement.

External water tanks is optional to meet different need and assure ample water-supply.

Tube and adapter with NSF authorization and top quality, reduce TOC level and assure water´s quality.

Standard pretreatment (including PP fiber, and active carbon cartridge), effectively protect RO membrane and run in low cost.

RO module with DOW´s membrane, ensure long life, stable operation and high desalinization rate.


Specifications

Model

Basic-RO15

Basic-RO30

Basic-RO45

Basic-RO15-IT

Basic-RO30-IT

Basic-RO45-IT

Output (25°C)*

15 liters/hour

30 liters/hour

45 liters/hour

RO water quality

Ion rejection rate

97%-99% (new RO membrane)

Organic rejection rate

>99%, when MW>200 Dalton

Particles and bacteria rejection rate

>99%

Feed water requirements

Tap water, temperature: 5-45°C, pressure: 1.0-4.0Kgf/cm2

Dimension and weight

RO15, RO30, RO45 series: Length×Width×Height: 340×320×470mm / Weight: about 13Kg
RO15-IT, RO30-IT, RO45-IT series: Length×Width×Height: 535×320×470mm / Weight: about 18Kg

Electrical requirements

AC100-240V, 50/60Hz

Power

RO15, RO15-IT series: 48W, RO30, RO30-IT series: 72W, RO45, RO45-IT series: 120W

Standard configuration

Main body (Including 1 set of cartridge) + built-in 12 liters pressure tank (IT)

Remarks:

*The value will be influenced by temperature and feed water’s quality.


Cartridges

Item no.

Commodity

Approximate replacement term /set

PC-10PP

10" spun fiber cartridge

About 2-6 months

PC-10AC-G

10"granular active carbon cartridge

About 6 months

PC-10AC-B

10" active carbon block cartridge

About 6 months

RO-100GPD

100 GPD reverse osmosis membrane

About 12-24 months

RO-200GPD

200 GPD reverse osmosis membrane

About 12-24 months

RO-300GPD

300 GPD reverse osmosis membrane

About 12-24 months

Remarks:

*The quality of inlet water will effect cartridge’s life.


HHitech-Products

Designing and manufacturing under ISO certification, top quality controlling commitment, ensure compliance with CE standards of EU, guarantee completely meeting with the highest grade I water standards of ASTM, CAP, CLSI, EP and USP.


HHitech-Service

As a responsible manufacturer with rich experience, operating in good faith, and the concept of common development, adhering to the customer-oriented and customer-needs, HHitech promises to provide professional comprehensive pre-sales and after-sales service in the whole business.

■ 12 months warranty except for consumables.

■ Timely guide for installation, usage and maintenance.

■ Free and continuous upgrade service for sold products.


We are an enterprise with strong comprehensive strength in R&D and manufacturing of Clinical Lab Test Reverse Osmosis Water Purification System. We can provide you with high-quality products with competitive prices and 100% satisfactory service. First class products need first-class technology and first-class companies need first-class management. We advocate that in the work of employees in all departments, we should support each other, cooperate with each other, take into account the overall situation, clear work tasks and common goals, respect others in the work, open-minded and sincere, and proactively work with others to improve the affairs.

Hot Tags: basic-ro series reverse osmosis water system, China basic-ro series reverse osmosis water system suppliers, manufacturers, factory, laboratory water purification durability, ultra purified reverse osmosis water, laboratory water purification convenient, laboratory reverse osmosis upgradability, laboratory reverse osmosis device, ultrapure water purification for educational laboratory

Send Inquiry