Commercial Large Scale Water Purification System 2000L Reverse Osmosis Plus EDI Machine for Laboratory Ultrapure

Commercial Large Scale Water Purification System 2000L Reverse Osmosis Plus EDI Machine for Laboratory Ultrapure

Basic-RO series is basic choice for general washing pure water. Its output ranges from 15 to 45 liters/hour. Its ion rejection rate: 97%-99% (new RO membrane), organic rejection rate>99% (when MW>200 dalton), particles and bacteria rejection rate>99%.
Send Inquiry
Description

While filling the product gap in the market, we actively innovate, lead the creation of new products in the industry, and provide the market with updated and more comprehensive laboratory ro plant, lab reverse osmosis equipment, Reverse Osmosis Water Purification Systems. We continue to develop and innovate, enrich the content of our self-developed products, enhance the concept of quality service, and establish a highly competitive technology system. We use our sincerity in exchange for the loyalty of users. In the fierce market competition, we sincerely make friends all over the world and sincerely cooperate with friends from all walks of life at home and abroad to create a better tomorrow.

Basic-RO series is basic choice for general washing pure water. Its output ranges from 15 to 45 liters/hour. Its ion rejection rate: 97%-99% (new RO membrane), organic rejection rate>99% (when MW>200 dalton), particles and bacteria rejection rate>99%.


image001

Models:

Basic-RO15 / 30 / 45

Basic-RO15 / 30 / 45-IT


Features and Advantages

Automatic microcomputer controlling system, backlight LCD real-time animation mode display.

Running status is showed in the LCD display, such as flushing, producing water, water full, water shortage, and check service.

2 way online water quality sensors, detect the quality of inlet water, RO water respectively.

Power on self-test, power reset, alarm when work more than 6 hours continuously, water shortage, low and high pressure.

Cartridges replacing alarm function, show cartridges´ used and residual life.

4 procedure of the reverse osmosis membrane´s self-flushing: power on, water shortage reset, water full stop and work more than 2 hours continuously, extend the life of RO membrane.

2 kind of installation type, Desk and wall-mounted (except for 45 series and built-in tank model).

High-strength metal shell with powder painting technics, achieve elegant appearance and meeting GLP standard

Pretreatment cartridges, RO module, all designed to modularization independently, easy for maintenance and replacement.

External water tanks is optional to meet different need and assure ample water-supply.

Tube and adapter with NSF authorization and top quality, reduce TOC level and assure water´s quality.

Standard pretreatment (including PP fiber, and active carbon cartridge), effectively protect RO membrane and run in low cost.

RO module with DOW´s membrane, ensure long life, stable operation and high desalinization rate.


Specifications

Model

Basic-RO15

Basic-RO30

Basic-RO45

Basic-RO15-IT

Basic-RO30-IT

Basic-RO45-IT

Output (25°C)*

15 liters/hour

30 liters/hour

45 liters/hour

RO water quality

Ion rejection rate

97%-99% (new RO membrane)

Organic rejection rate

>99%, when MW>200 Dalton

Particles and bacteria rejection rate

>99%

Feed water requirements

Tap water, temperature: 5-45°C, pressure: 1.0-4.0Kgf/cm2

Dimension and weight

RO15, RO30, RO45 series: Length×Width×Height: 340×320×470mm / Weight: about 13Kg
RO15-IT, RO30-IT, RO45-IT series: Length×Width×Height: 535×320×470mm / Weight: about 18Kg

Electrical requirements

AC100-240V, 50/60Hz

Power

RO15, RO15-IT series: 48W, RO30, RO30-IT series: 72W, RO45, RO45-IT series: 120W

Standard configuration

Main body (Including 1 set of cartridge) + built-in 12 liters pressure tank (IT)

Remarks:

*The value will be influenced by temperature and feed water’s quality.


Cartridges

Item no.

Commodity

Approximate replacement term /set

PC-10PP

10" spun fiber cartridge

About 2-6 months

PC-10AC-G

10"granular active carbon cartridge

About 6 months

PC-10AC-B

10" active carbon block cartridge

About 6 months

RO-100GPD

100 GPD reverse osmosis membrane

About 12-24 months

RO-200GPD

200 GPD reverse osmosis membrane

About 12-24 months

RO-300GPD

300 GPD reverse osmosis membrane

About 12-24 months

Remarks:

*The quality of inlet water will effect cartridge’s life.


HHitech-Products

Designing and manufacturing under ISO certification, top quality controlling commitment, ensure compliance with CE standards of EU, guarantee completely meeting with the highest grade I water standards of ASTM, CAP, CLSI, EP and USP.


HHitech-Service

As a responsible manufacturer with rich experience, operating in good faith, and the concept of common development, adhering to the customer-oriented and customer-needs, HHitech promises to provide professional comprehensive pre-sales and after-sales service in the whole business.

■ 12 months warranty except for consumables.

■ Timely guide for installation, usage and maintenance.

■ Free and continuous upgrade service for sold products.


Based on the original foundation, we further strengthen the R&D, production, and sales teams, keeping up with the pace of the development of the Commercial Large Scale Water Purification System 2000L Reverse Osmosis Plus EDI Machine for Laboratory Ultrapure industry. Guided by market demand, we integrate resources and pursue to create more, better and more suitable high-quality products for consumers. Our company's personnel at all levels communicate with each other and understand the quality policy, so as to better implement the quality policy.

Hot Tags: basic-ro series reverse osmosis water system, China basic-ro series reverse osmosis water system suppliers, manufacturers, factory, lab ultrapure water purification documentation, lab water deioniser, ro water filter machine, water ro purifier for home, laboratory deionized water purifcation system, wood resins sensors for laboratory deionized water system

Send Inquiry