On the basis of extensive learning from advanced technology and experience at home and abroad, the quality of our Type II water system, lab water treatment system, laboratory ro plant meets the standard and has been trusted by our customers since they were put on the market! 'Focus and innovation' is our long-term market development strategy, so that our products always maintain the leading position in the industry. Caring for the life and health of employees is the first responsibility of the company. Only through cooperation can there be win-win results because of the increasingly fierce global market competition.
With 5.0 inch touch screen system, 3 way water quality sensor, 2 way flow sensor for quantified dispensing, single stage RO system and 1 pump, Master Touch-Q series deionized water system is superior choice of deionized water for general grade experiments.
With tap water inlet, its output ranges from 15 to 30 liters/hour. It can produce single stage RO water and deionized water. The single stage RO water’s ion rejection rate is more than 97%, and the deionized water’s resistivity is above 16MΩ.cm, near to18.2MΩ.cm. It completely meets the requirements of general chemical or biological experiments for pure water.

Models:
Master Touch-Q15 / 30
Master Touch-Q15 / 30UT
Features and Advantages
Colorful touch screen 5.0 inch colorful high-resolution touch screen (16:9) controlling system, achieve finger-touch new experience. |
|
Comprehensive monitoring system 3 way online water quality sensor, detect the quality of feed water, RO water, deionized water respectively. And warn once water quality’s standard exceeding. 2 way flow sensor, achieve quantified dispensing of RO water, deionized water. |
|
Easy-to-replacing cartridge Independent pretreatment design, and integrated subsequent purification unit design, with fast inserted adapters, easy to replace |
|
Whole plastic shell with high-strength Excellent ergonomic design, avoid rusting and keep clean, to meet GLP standard. |
|
USB interface and SD card Auto running data storing function with built-in SD card, and data can be exported through the USB interface. |
|
All Cartridges replacing alarm function, based on time, or water quality, show cartridges´ used and residual life.
Multiple alarm function: no feed water, full water, water quality´s standard exceeding, and cartridge life ending.
Auto self-flushing of RO membrane function (interval and continuous time setting), extend RO membrane´s life.
Comprehensive Information query and management function, master system status, water quality, cartridges usage and alarm information.
System time setting (year/month/day/hour/minute), timing standby (0-60 minute), and timing shutdown (0-24 hour) function.
Level II password, protect all the parameters setting, and prohibit any unauthorized setting change.
2 kind of pure water tank (liquid level PE tank and pressure tank). Also external tanks is optional.
3 door and easy-to-replacing cartridge design, convenient to maintain system and replace cartridges.
Tube and adapter with NSF authorization and top quality, reduce TOC level and assure water´s quality.
Optimized pretreatment (including PP fiber, KDF and active carbon cartridge), effectively protect RO membrane.
RO module with DOW´s membrane, ensure long life, stable operation and high desalinization rate.
Single wavelength (254nm) ultraviolet lamp module, restrain bacteria´s increase.
(0.45+0.1)µm double layer PES terminal disinfection filter, assure that terminal pure water is absolutely axenic.
Flow Schematic

Specifications
Model | Master Touch-Q15 | Master Touch-Q15UT | Master Touch-Q30 | Master Touch-Q30UT |
Output (25°C)* | 15 liters/hour | 30 liters/hour | ||
Flow rate | Up to 2 liters/minute (with pressure tank) | |||
Pure water outlet | 2: reverse osmosis water, deionized water | |||
Deionized water quality |
| |||
Resistivity | 16-18.2MΩ.cm | |||
Bacteria | N/A | <0.01cfu/ml | N/A | <0.01cfu/ml |
Particle (>0.1µm) | N/A | <1/ml | N/A | <1/ml |
RO water quality |
| |||
Ion rejection rate | 97%-99% (new RO membrane) | |||
Organic rejection rate | >99%, when MW>200 Dalton | |||
Particles and bacteria rejection rate | >99% | |||
Feed water requirements | Tap water, temperature: 5-45°C, pressure: 1.0-4.0Kgf/cm2 | |||
Dimension and weight | Length×Width×Height: 500×360×540mm / Weight: about 20Kg | |||
Electrical requirements | AC100-240V, 50/60Hz | |||
Power | 120W | |||
Standard configuration | Main body (Including 1 set of cartridge) + 15 liters pressure tank | |||
Remarks:
*The value will be influenced by temperature and feed water’s quality.
Cartridges
Item no. | Commodity | Approximate replacement term /set |
PC-M-PP | 5µm spun fiber cartridge | 2-6 months |
PC-M-KDF | KDF+ granular active carbon mixed cartridge | 12 months |
PC-M-AC-G | Granular active carbon cartridge | 6 months |
RO-100GPD | 100 GPD reverse osmosis membrane | 12-24 months |
RO-200GPD | 200 GPD reverse osmosis membrane | 12-24 months |
PTC-AC-HZB1 | Reducing TOC cartridge | 9000 liters pure water |
PTC-MBR-M | Mixed bed resin cartridge | 1000 liters pure water |
PTC-MBR-M4 | 4-in-I mixed bed resin cartridge module | 4000 liters pure water |
TF-(0.45+0.1)µm-S | (0.45+0.1)µm terminal filter | - |
LAMP-254-10W-M | 254 nm wavelength uv lamp | 9000 hours |
Remarks:
*The quality of inlet water will effect cartridge’s life.
HHitech-Products
Designing and manufacturing under ISO certification, top quality controlling commitment, ensure compliance with CE standards of EU, guarantee completely meeting with the highest grade I water standards of ASTM, CAP, CLSI, EP and USP.
HHitech-Service
As a responsible manufacturer with rich experience, operating in good faith, and the concept of common development, adhering to the customer-oriented and customer-needs, HHitech promises to provide professional comprehensive pre-sales and after-sales service in the whole business.
■ 12 months warranty except for consumables.
■ Timely guide for installation, usage and maintenance.
■ Free and continuous upgrade service for sold products.
The business keeps to the operation concept 'scientific management, premium quality and efficiency primacy, customer supreme' for Cyclic Corrosion Test (Salt spray /fog test) Pure Ultrapure Water Deionizer Z66. We always follow the quality policy of 'strict, rigorous, meticulous, and exquisite', and have won the trust and respect of customers through advanced processing technology, high-quality products and good service. We make the company into an army-like execution, school-like learning, and family-like happy working environment.
Hot Tags: master touch-q series deionized water system, China master touch-q series deionized water system suppliers, manufacturers, factory, optimized water purification for laboratory, training for laboratory water purification system operation, type 2 pure water system, ultrapure water system in laboratory environment, reverse osmosis water filter system, laboratory deionized water purification