We have continuously improved the quality of our lab deioniser, lab deionized water machine, lab ultra pure water system over the years by increasing our independent innovation and applying standards and technologies to the process of product production. After years of efforts, we have a perfect factory management system and production process, can meet the needs of different customers. We have a strong R&D team that can develop and manufacture products based on drawings or samples provided by our customers. The company adheres to customer-centric, actively focuses on customer needs, responds in time, and provides customers with thoughtful and timely services. We want to establish a close strategic partnership with our customers for growth, firm ideals and beliefs, and realize the value of life.
With LCD controlling system, 3 way water quality sensors, timing and quality dispensing, single stage RO system and 2 pumps, Master-S series ultrapure water system is sub-superior choice of ultrapure water for high grade experiments. With tap water inlet, its output ranges from 15 to 30 liters/hour. It can produce single stage RO water and ultrapure water. The single stage RO water´s ion rejection rate is more than 97%, and the ultrapure water´s resistivity absolutely reaches to 18.2MΩ.cm. It completely meets the highest grade I standard of ASTM, CAP, CLSI, EP and USP.

Models:
Master-S15 / 30
Master-S15 / 30UF
Master-S15 / 30UV
Master-S15 / 30UVF
Features and Advantages
Micro-computer control system with LCD display LCD (resolution: 240×128, dimension: 106×57mm), intuitively display the system running state and various real-time parameters. |
|
Comprehensive monitoring system 3 way online water quality sensors, detect the quality of feed water, RO water, deionized water, or ultrapure water respectively. And warn once water quality´s standard exceeding. Water dispensing function- timing and quality (time range: 1-99min, water quality range: 0.1-18.2MΩ.cm).water. |
|
Easy-to-replacing cartridge Independent pretreatment design, and integrated subsequent purification unit design, with fast inserted adapters, easy to replace. |
|
Single stage RO and 2 pumps system 1st pump, to achieve single stage RO system, easy to maintain. 2nd pump, to achieve system sanitizing and circulation. |
|
Whole plastic shell with high-strength Excellent ergonomic design, avoid rusting and keep clean, to meet GLP standard. |
|
Cartridges replacing alarm function, based on time and water quality, show cartridges´ used and residual life.
Multiple alarm function: no feed water, full water, water quality´s standard exceeding, and cartridge life ending.
Auto self-flushing of RO membrane function, extend RO membrane´s life.
Auto running data storing function through RS232/USB communication port to computer for 1 year at least (optional).
System sanitizing procedure, achieve the disinfection of ultrapure water´s tube and valve.
System circulation function, achieve ultrapure water´s circulation to keep top quality of ultrapure water.
Level II password, protect all the parameters setting, and prohibit any unauthorized setting change.
External water tanks is optional to meet different need and assure ample water-supply.
3 doors and easy-to-replacing cartridge design, convenient to maintain system and replace cartridges.
Tube and adapter with NSF authorization and top quality, reduce TOC level and assure ultrapure water´s quality.
Optimized pretreatment (including PP fiber, KDF and active carbon cartridge), effectively protect RO membrane.
RO module with DOW´s membrane, ensure long life, stable operation and high desalinization rate.
4 in 1 ultrapure cartridge (can be divided to 4 independent cartridge) with DOW´s top polishing resin, ensure ultrapure water´s quality up to 18.2 MΩ.cm, with the lowest TOC level.
Double wavelength (185&254nm) ultraviolet lamp module, restrain bacteria´s increase and reduce TOC.
MWCO 5000D ultrafiltration module, effectively eliminate endotoxin, and suitable for precise cell cultivating and IVF.
(0.45+0.1)µm double layer PES terminal disinfection filter, assure that terminal pure water is absolutely axenic.
Flow Schematic

Specifications
Model | Standard | Eliminating endotoxin | Low TOC | Synthesizing |
Master-S15 | Master-S15UF | Master-S15UV | Master-S15UVF | |
Master-S30 | Master-S30UF | Master-S30UV | Master-S30UVF | |
Output (25°C)* | 15series-15 liters/hour, 30 series-30 liters/hour | |||
Flow rate | Up to 2 liters/minute (with pressure tank) | |||
Pure water outlet | 2: reverse osmosis water, ultrapure water | |||
Ultrapure water quality | ||||
Resistivity (25°C) | 18.2MΩ.cm | |||
TOC* | <10ppb | <10ppb | <3ppb | <3ppb |
Bacteria | <0.01cfu/ml | |||
Particle (>0.1μm) | <1/ml | |||
Endotoxin | N/A | <0.001Eu/ml | N/A | <0.001Eu/ml |
RNases | N/A | <1pg/ml | N/A | <1pg/ml |
DNases | N/A | <5pg/ml | N/A | <5pg/ml |
RO water quality | ||||
Ion rejection rate | 97%-99% (new RO membrane) | |||
Organic rejection rate | >99%, when MW>200 Dalton | |||
Particles and bacteria rejection rate | >99% | |||
Feed water requirements | Tap water, temperature: 5-45°C, pressure: 1.0-4.0Kgf/cm2 | |||
Dimension and weight | Length×Width×Height: 500×360×540mm / Weight: about 20Kg | |||
Electrical requirements | AC100-240V, 50/60Hz | |||
Power | 120W | |||
Standard configuration | Main body (Including 1 set of cartridge)+15 liters pressure tank | |||
Remarks:
*The value will be influenced by temperature and feed water´s quality.
Cartridges
Item no. | Commodity | Approximate replacement term /set |
PC-M-PP | 5µm spun fiber cartridge | 2-6 months |
PC-M-KDF | KDF+ granular active carbon mixed cartridge | 12 months |
PC-M-AC-G | Granular active carbon cartridge | 6 months |
RO-100GPD | 100 GPD reverse osmosis membrane | 12-24 months |
RO-200GPD | 200 GPD reverse osmosis membrane | 12-24 months |
PTC-AC-HZB1 | Reducing TOC cartridge | 9000 liters pure water |
PTC-MBR-M | Mixed bed resin cartridge | 1000 liters pure water |
PTC-MBR-M4 | 4-in-I mixed bed resin cartridge module | 4000 liters pure water |
PTC-UPPR-M | Ultrapure polishing resin cartridge | 1000 liters pure water |
PTC-UPPR-M4 | 4-in-1 ultrapure polishing resin cartridge | 4000 liters pure water |
TF-(0.45+0.1)µm-S | (0.45+0.1)µm terminal filter | - |
UF-5000D | MWCO5000D UF cartridge | - |
LAMP-(185nm&254nm) -10W-M | Double wavelength (185&254)nm uv lamp | 9000 hours |
LAMP-254-10W-M | 254 nm wavelength uv lamp | 9000 hours |
Remarks:
*The quality of inlet water will effect cartridge’s life.
*When inlet water’s TDS>200ppm, Replace term of filter will be suggested to decrease, or outside pre-filter is added. Or water quality and life of ultrapure cartridge will be affected.
HHitech-Products
Designing and manufacturing under ISO certification, top quality controlling commitment, ensure compliance with CE standards of EU, guarantee completely meeting with the highest grade I water standards of ASTM, CAP, CLSI, EP and USP.
HHitech-Service
As a responsible manufacturer with rich experience, operating in good faith, and the concept of common development, adhering to the customer-oriented and customer-needs, HHitech promises to provide professional comprehensive pre-sales and after-sales service in the whole business.
■ 12 months warranty except for consumables.
■ Timely guide for installation, usage and maintenance.
■ Free and continuous upgrade service for sold products.
We strive to promote the rapid development of the company in a new starting point to achieve new breakthroughs, and lay a good foundation for the company to become an excellent manufacturer of providing Water Purification Station/Drinking Water Purification System with characteristics. We have done every work steadily and gradually won the trust of the majority of users. Our continuous independent innovation promotes the development of product optimization and the core technology of our company's design and development ranks in the forefront of the world.
Hot Tags: master-s series ultrapure water system, China master-s series ultrapure water system suppliers, manufacturers, factory, advanced laboratory reverse osmosis system, ro water purifier with storage tank, laboratory reverse osmosis clarity improvement, laboratory reverse osmosis upgradability, laboratory reverse osmosis microorganism removal, 8 stage reverse osmosis system