Ultra pure water machine in later use will lead to equipment performance decline due to various factors, so in order to ensure the extension of the service life of the equipment, daily use should pay attention to the maintenance and maintenance of the equipment, so what factors lead to ultra pure water machine performance decline?

1. Impurities and content of influent water source

Because the water quality varies from place to place, if there is a change in the quality of the raw water, the configuration plan of the ultrapure water machine pre-treatment device should be adjusted in time, otherwise the change in the content and type of influent impurities will cause the pretreatment and filtration to be inadequate and overload operation It will affect the service life of the first-stage filter element of the ultrapure water machine, and the filter element will be replaced more frequently, which will increase the later use cost of the ultrapure water machine.

2. Inlet water temperature

The operation of the ultrapure water machine also has certain requirements on the inlet water temperature. The temperature is recommended to be controlled between 1 and 45°C. It is recommended to ensure that the water temperature is within a controllable range, otherwise the temperature will affect the normal working efficiency of the ultrapure water equipment.

3. Replace the spare parts of the ultrapure water machine in time

In accordance with the manufacturer's recommended use cycle, timely replacement of spare parts can ensure the water quality of the ultrapure water machine and ensure the performance of the equipment.

4. Working pressure value

The reverse osmosis technology used by the ultrapure water machine is a membrane separation filtration technology that uses pressure difference as the power. The reverse osmosis membrane works by pressure. Only the pressure value is suitable can achieve a good filtering and purification effect. The ultrapure water machine is too small. The water production will decrease. If the pressure is too high, the reverse osmosis membrane will be lost, the service life will be shortened, and the cost of the machine will increase. When the ultrapure water machine is working, the pressure gauge should indicate about 4kg/cm2. Small will affect the normal operation of the device.