Ro (reverse osmosis) reverse osmosis technology is a membrane separation and filtration technology powered by pressure gauge difference. It is originated from the research of aerospace technology in the 1960s in the United States, and then gradually becomes civilian. It has been widely used in scientific research, medicine, food, beverage, desalination and other fields.
Ro RO membrane has a small pore size of nanometer (1 nm = 10-9 m). Under certain pressure, H2O molecules can pass through RO membrane, while inorganic salt, heavy metal ions, organic matter, colloid, bacteria, virus and other impurities in the source water cannot pass through RO membrane, so that the pure water that can be transmitted and concentrated water that cannot be transmitted can be strictly distinguished.
Conductivity of the general tap water after RO membrane filtration 5 μ S / cm (conductivity of effluent after RO membrane filtration = conductivity of influent) × The desalination rate of the imported RO membrane can reach 99% or more, and the operation can guarantee 97% or more within 5 years. If the conductivity of the outlet water is relatively high, the second stage reverse osmosis can be adopted, and after simple treatment, the hydropower conductivity is less than 1 μ S/cm), which meets the third level water standard of national laboratory. After the circulation filtration of atomic ion exchange column, the water resistivity of the effluent can reach 18.2m.cm, which is higher than the national standard for laboratory water use (GB 6682-92).
The following three theories are popular in the interpretation of the mechanism of reverse osmosis separation in academia
1. Dissolution diffusion model
Lonsdale et al. Proposed a solution diffusion model to explain the reverse osmosis phenomenon. He considered the active surface cortex of reverse osmosis as a dense porous membrane, and assumed that both solute and solvent could dissolve in the homogeneous porous membrane surface layer, and each diffusion through the membrane under the chemical potential caused by concentration or pressure. The difference of solubility and diffusion of solute and solvent in the film phase affect their energy through the membrane. The specific process is divided into steps: the solute and solvent adsorb and dissolve on the surface of the material liquid side of the membrane; In the second step, there was no interaction between solute and solvent, and they passed through the active layer of RO membrane by molecular diffusion under the promotion of their chemical potential difference; The third step is to desorption solute and solvent on the surface of the membrane through the liquid side.
In the process of solute and solvent passing through the membrane, it is generally assumed that the third step and the second step will be the rate of transmission. That is, the solute and solvent pass through the membrane by molecular diffusion under the promotion of chemical potential difference. Because of the selectivity of the membrane, the gas mixture or liquid mixture can be separated. The permeability of the material depends not only on the diffusion coefficient, but also on the solubility of the material in the membrane.
2. Theory of preferential adsorption capillary flow
When different kinds of substances are dissolved in the liquid, the surface tension will change. For example, the solution of organic substances such as alcohol, acid, aldehyde, grease can reduce the surface tension, but dissolve some inorganic salts, but make the surface tension slightly increase, because the dispersion of solute is uneven, that is, the concentration of solute in the surface layer of solution is different from that of the internal concentration of the solution, which is the surface adsorption phenomenon of the solution. When the water solution contacts the porous polymer membrane, if the chemical properties of the membrane make the membrane negative adsorption to solute and the positive adsorption of water is preferred, a certain thickness of pure water layer will be formed at the interface between the membrane and the solution. Under the action of external pressure, it will pass through the pores on the surface of the film, so that pure water can be obtained.
3. Hydrogen bond theory
In cellulose acetate, due to the action of hydrogen bond and van der Waals force, there are two parts in the film, namely, the crystalline region and the amorphous phase region. The solid binding and parallel arrangement of macromolecules is the crystal phase region, while the amorphous phase region is completely disordered between the macromolecules, and water and solute cannot enter the crystal phase region. Near the cellulose acetate molecule, the oxygen atoms on the carbonyl group of cellulose acetate and water form hydrogen bonds and form so-called binding water. When cellulose acetate adsorbs the layer water molecules, it will cause the water molecular entropy to decrease greatly, forming a structure similar to ice. In the pore space with large amorphous phase, the occupancy of combined water is very low. There is water with common structure in the center of the pore. The ions or molecules that can not form hydrogen bond with cellulose acetate film enter into the binding water, and migrate in an orderly diffusion way. The membrane is passed through the membrane by changing the position of hydrogen bond formed by cellulose acetate.
Under pressure, the water molecules in the solution and the oxygen atoms on the carbonyl group form hydrogen bonds. The hydrogen bonds formed by the original water molecules are disconnected, and the water molecules are dissociated and moved to the next activation point and form new hydrogen bonds. Thus, they are formed and disconnected through a series of hydrogen bonds, The water molecules leave the dense active layer on the surface of the membrane and enter the porous layer of the membrane. Because the porous layer contains a large amount of capillary water, the water molecules can flow out of the membrane smoothly.