As a provider of Type 2 pure water systems, I am often asked about the principles behind their purification processes. In this blog post, I will delve into the key mechanisms that make Type 2 pure water systems so effective in producing high - quality water for a variety of laboratory and industrial applications.

The Basics of Type 2 Pure Water

Type 2 pure water, also known as deionized water, has a relatively low level of impurities, specifically with a resistivity of 1 - 18.2 MΩ·cm at 25°C. It is widely used in laboratories for general analytical work, preparation of reagents, and other applications where moderately pure water is sufficient. Type 2 pure water systems are designed to remove a wide range of contaminants, including ions, particles, and some organic compounds, to achieve this level of purity.

Pre - treatment Stage

The purification process of a Type 2 pure water system typically begins with a pre - treatment stage. This stage is crucial as it helps to protect the more sensitive purification components downstream and extends their lifespan.

Sediment Filtration

The first step in pre - treatment is often sediment filtration. A sediment filter is used to remove large particles such as sand, silt, and rust from the incoming water. These particles can cause damage to the subsequent purification membranes and other components if not removed. Sediment filters are usually made of materials like polypropylene and are available in different micron ratings, with common ratings being 1 - 5 microns.

Activated Carbon Filtration

After sediment filtration, the water passes through an activated carbon filter. Activated carbon has a large surface area with numerous pores, which allows it to adsorb organic compounds, chlorine, and some heavy metals. Chlorine, in particular, is a concern because it can damage reverse osmosis membranes and ion - exchange resins. By removing chlorine and other organics, the activated carbon filter helps to maintain the performance of the downstream purification units.

Reverse Osmosis (RO) Process

Reverse osmosis is a key technology in many Type 2 pure water systems. It is a membrane - based filtration process that uses pressure to force water through a semi - permeable membrane, leaving behind most of the dissolved salts, ions, and other contaminants.

How Reverse Osmosis Works

The RO membrane has extremely small pores that allow water molecules to pass through while blocking the passage of larger molecules and ions. When pressure is applied to the feed water on one side of the membrane, water is forced through the membrane, and the concentrated solution of contaminants is discharged as wastewater. Reverse osmosis can remove up to 95 - 99% of dissolved salts, bacteria, and most organic compounds.

Importance in Type 2 Pure Water Systems

RO is an essential step because it significantly reduces the load on the subsequent ion - exchange process. By removing a large portion of the ions in the water, the RO system helps to extend the life of the ion - exchange resins and improve the overall efficiency of the purification system.

Ion - Exchange Process

After reverse osmosis, the water may still contain some residual ions. The ion - exchange process is used to further remove these ions and achieve the desired level of purity.

Cation and Anion Exchange Resins

Ion - exchange resins are small beads made of a polymer matrix with charged functional groups attached. There are two main types of ion - exchange resins: cation exchange resins and anion exchange resins. Cation exchange resins exchange cations (positively charged ions) such as sodium, calcium, and magnesium for hydrogen ions. Anion exchange resins exchange anions (negatively charged ions) such as chloride, sulfate, and carbonate for hydroxide ions.

When the water passes through the cation exchange resin bed, the cations in the water are replaced by hydrogen ions. Then, as the water passes through the anion exchange resin bed, the anions are replaced by hydroxide ions. The hydrogen ions and hydroxide ions combine to form water, effectively removing the ions from the water.

Mixed - Bed Ion - Exchange Resins

In some Type 2 pure water systems, mixed - bed ion - exchange resins are used. Mixed - bed resins contain a mixture of cation and anion exchange resins in a single resin bed. This arrangement provides a more efficient ion - exchange process as the cations and anions are removed simultaneously, resulting in a higher level of purity.

EDI (Electrodeionization) Technology

Some advanced Type 2 pure water systems also incorporate EDI technology. EDI is an electrochemical process that combines ion - exchange resin beds with an electric field to continuously regenerate the ion - exchange resins and remove ions from the water.

Center Series Deionized Water SystemEdi Touch-Q Series Deionized Water System

How EDI Works

In an EDI module, the water flows through a chamber containing ion - exchange resins. An electric field is applied across the chamber, which causes the ions in the water to migrate towards the electrodes. As the ions move through the resin bed, they are removed from the water. At the same time, the electric field also causes the regeneration of the ion - exchange resins by splitting water molecules into hydrogen and hydroxide ions.

Advantages of EDI in Type 2 Pure Water Systems

EDI eliminates the need for chemical regeneration of ion - exchange resins, which is not only more environmentally friendly but also reduces operational costs. It also provides a continuous and stable supply of high - purity water, making it suitable for applications that require a constant quality of water.

Our Type 2 Pure Water Systems

At our company, we offer a range of Type 2 pure water systems to meet different customer needs. Our Edi Touch - Q Series Deionized Water System is a state - of - the - art system that combines advanced RO, ion - exchange, and EDI technologies. It is designed for laboratories with high - volume water requirements and offers a high level of reliability and performance.

The Center Series Deionized Water System is a more compact and cost - effective option. It is suitable for small to medium - sized laboratories and still provides excellent water quality.

Our Center - EDI Series Deionized Water System combines the benefits of EDI technology with a user - friendly design. It is ideal for applications where a stable supply of high - purity water is required.

Contact for Procurement

If you are in the market for a Type 2 pure water system, our team of experts is ready to assist you. We can help you choose the right system based on your specific requirements, provide installation and maintenance services, and ensure that you get the most out of your investment. Contact us today to start the procurement process and discuss how our Type 2 pure water systems can meet your needs.

References

  1. ASTM D1193 - 19 Standard Specification for Reagent Water
  2. Miller, S. & Kent, J. (2005). Water Purification for Laboratory Applications. Wiley - VCH.
  3. Fahrenbruch, C. (2010). Principles of Reverse Osmosis and Nanofiltration. Desalination. 261(1): 2 - 9.
Send Inquiry
Jennifer Hu
Jennifer Hu
I am a Customer Support Representative at Hitech Instruments, where I assist customers with their inquiries about our products. I enjoy helping scientists find the right solutions for their laboratory needs.
Contact Us
  • Tel: +86-21-57795001
  • Fax: +86-21-57795003
  • sales@high-tech.cn
  • Add: Building 113, Lane 255, South Sizhuan Road, 201612, Songjiang District, Shanghai, China